Note: You are seeing this text-only version of our site because you are using an older browser that is not standards-compliant.
How to upgrade to a FREE standards-compliant browser.
Some Netscape 7 and Mozilla users may see this warning in error. Click here to fix the problem.

Modbus Organization

Advantages of Joining | Join Form | Toolkit | Subscribe to Newsletter

Text Size: smallmediumlarge
 Back to Company Directory

Equustek Solutions Inc.

Member: No

Address:

Suite 815 - 1200 W 73rd Avenue
Vancouver, BC V6P 6G5 CANADA

Phone: 604-266-8547
Fax: 604-266-9547
Web Site: www.equustek.com
Contact:
Email: info@equustek.com

Description:

Equustek specializes in the manufacture and design of gateways, bridges, and custom protocol conversion communication products for complete system integration. They allow industrial automation equipment the ability to exchange data over popular industrial networks. The company's expertise is interfacing PCs, SCADA Systems, AB PLCs, SLCs, computers, modems, variable speed drives and OEM equipment to Modicon's Modbus, Allen-Bradley's Data Highway Plus (DH+), DH-485, and Remote I/O. Equustek also develops adapters that interface Industrial Ethernet (Ethernet/IP, TCP/IP, Modbus TCP/IP), Profibus, and DeviceNet protocols.

 

Product Name Type Connectivity Product Description
DL2000-CMXNetwork GatewayModbusThe DL2000-CMX provides an AC powered, freestanding Modbus serial interface for computers, MMIs, and OEM based applications that require access to a node on AB's DH+ network. The CMX can be set to be either a Master or a Slave on the Modbus serial link, as well as communicate using either RTU or ASCII protocols. The CMX in Master Mode can read from and write to registers and coils in any Modbus Slave device connected. Slave Mode allows a Modbus Master device to read from or write to files in a A-B PLC5 or SLC 5/04 connected to the DH+ network.
DL4000-DMX DF1Network GatewayModbusThe DL4000-DMX has two configuration modes that allow Modbus devices to communicate with A-B's DF1 protocol (CH0s of PLCs, SLCs, Micrologixs, etc.) Modbus Master Mode configures the DL4000-DMX to act as a Master on the Modbus Network. Commands can be generated inside the PLC (DF1 Device) to access/change data inside Modbus Slave devices using either Modbus ASCII or RTU protocol. Modbus Slave Mode configures the DL4000-DMX to act as a Slave on the Modbus Network. Commands can be generated inside a Modbus Master Device to access/change data inside the SLC (DF1 device).
DL4000-MMXNetwork GatewayModbusThe DL4000-MMX allows Modbus Master RTU devices to communicate to multiple Modbus Slave ASCII Devices.
DL4500-MEDH+Network GatewayModbus TCP/IPEquustek's gateway interfaces your Modbus TCP/IP Network to A-B's Data Highway Plus DH+, extending the life of Allen-Bradley PLCs without Ethernet Interfaces. The DataLink solution allows applications such as RSLogix, RSLinx, and RSView to access devices on a DH+ network from an Ethernet/IP LAN, enabling users to run MMI applications or program and monitor PLCs on a DH+ network from an Ethernet LAN station. Other MMIs tested include Wonderware, Kepware, and Intellution. The DL4500-MEDH+ combines the Lantronix Ethernet Microprocessor with Equustek's DH+ token-ring technology.
DL4500-MEDH-485Network GatewayModbus TCP/IPEquustek's gateway interfaces your Modbus TCP/IP Network to A-B's Data Highway Plus DH+, extending the life of Allen-Bradley PLCs without Ethernet Interfaces. The DataLink solution allows applications such as RSLogix, RSLinx, and RSView to access devices on a DH+ network from an Ethernet/IP LAN, enabling users to run MMI applications or program and monitor PLCs on a DH+ network from an Ethernet LAN station. Other MMIs tested include Wonderware, Kepware, and Intellution. The DL4500-MEDH+ combines the Lantronix Ethernet Microprocessor with Equustek's DH+ token-ring technology.
DL3500Network GatewayModbusEquustek's DL3500 comes in 4 models. The DL3500-Modbus/DH+ and DH-485 become Modbus Masters for devices on A-B's DH+ or DH-485 networks. The DL3500-Modbus/DH+ and DH-485 become Modbus Slave devices for access to PLCs on A-B's DH+ or DH-485 networks. Master mode is used when a device on the DH+ network is going to initiate all communications with one or many Modbus slave devices. Slave mode is used when a device on the Modbus network is going to initiate all communications with one or many SLCs, PLCs or other DH+ devices. The DL3500-Modbus/DH+ or DH-485 is a two port device that bridges your Modicon Modbus devices to A-B DH+ network. The Modbus model can either be used as Modbus Master or Slave as well as having both Modbus ASCII and RTU protocols.